Volume 3, Issue 1 (Scientific Journal of Hamadan University of Medical Sciences-Autumn & Winter 1996)                   Avicenna J Clin Med 1996, 3(1): 0-0 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Golmohamadi R. Assessment of Impact Noise in Pneumatic Breaker. Avicenna J Clin Med 1996; 3 (1)
URL: http://sjh.umsha.ac.ir/article-1-1077-en.html
Abstract:   (4854 Views)

For assessing of impact Noise which is produced by pneumatic breaker, a study was performed in Hamadan during summer 1995.32 Kg pneumatic breakers of five services organizations were studied. Results show: background Noise, including Environmental and Air compressor Noise are in the range of 87 dBA-101 dBA and different in various type of cases. According to this study, SPL of breaker during operation are between 107 dBC and 111.5 dBC. Measurement of SPL in distance of 20m from sources are in the range of 83 dNA- 89.5 dBA.

     
Type of Study: Original | Subject: Other Clinical Specialties

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Avicenna Journal of Clinical Medicine

Designed & Developed by : Yektaweb