<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Avicenna Journal of Clinical Medicine</title>
<title_fa>مجله پزشكي باليني ابن سينا</title_fa>
<short_title>Avicenna J Clin Med</short_title>
<subject>Medical Sciences</subject>
<web_url>http://sjh.umsha.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2588-722X</journal_id_issn>
<journal_id_issn_online>2588-7238</journal_id_issn_online>
<journal_id_pii>-</journal_id_pii>
<journal_id_doi>10.53208/ajcm</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>-</journal_id_sid>
<journal_id_nlai>-</journal_id_nlai>
<journal_id_science>-</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1381</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2002</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>9</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ایجاد تصویر سه بعدی با استفاده از سیستم های فراصوت دو بعدی معمولی</title_fa>
	<title>Construction Three-Dimentional Images Using Conventional Two - Dimentional Ultrasound Systems.</title>
	<subject_fa>سایر تخصص هاي باليني</subject_fa>
	<subject>Other Clinical Specialties</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Original </content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; استفاده از امواج فراصوت یکی از روشهای مرسوم در تصویربرداری پزشکی است. تصاویر سونوگرافی دارای آرتیفکت های بیشماری هستند. ساخت تصاویر سه بعدی روشی برای تجسم بهتر و تفسیر راحت تر تصاویر می باشد .&amp;nbsp; هدف از انجام این تحقیق بررسی وساخت تصاویر سه بعدی با استفاده از سیستم های فراصوت دو بعدی معمولی و با توجه به امکانات موجود در ایران است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; برای ساخت&amp;nbsp; تصاویر سه بعدی از یک&amp;nbsp; دستگاه سونوگرافی، با پروب خطی محدب استفاده گردید.تصاویر سه بعدی از اجسامی مثل: استوانه آلومینیومی ، کره کائوچویی ، دست انسان ، کلیه گوسفند، رگ کاروتید و کلیه انسان گرفته شد. جای تصاویر با استفاده از یک&amp;nbsp; اسکنر که سه درجه آزادی داشت، مشخص گردید. از یک درجه آزادی برای حرکت انتقالی پروب بهره گرفته شد. حرکت اسکنر توسط یک موتور پله ای &lt;span dir=&quot;LTR&quot;&gt;( stepping motor)&lt;/span&gt; انجام گردید. برنامه مرتبط با حرکت اسکنر با زبان &lt;span dir=&quot;LTR&quot;&gt;C&lt;/span&gt; نوشته شد. در فاصله یک میلیمتری هر تصویر اخذ و به کامپیوتر منتقل شد. پس از آن با انجام فیلتراسیون و درون یابی نهایتا&amp;quot; تصاویر در مقاطع دیگر بازسازی و با روش نمایش برش ها نشان داده شد. پردازش تصاویر و اعمال مرتبط با آن با &lt;span dir=&quot;LTR&quot;&gt;MATLAB 4.1&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;MATLAB 5.3&lt;/span&gt; انجام گرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; پس از اخذ تصاویر در بعدهای دیگر از دو جنبه به بررسی تصاویر پرداخته شد. در گام اول اندازهتصاویر بازسازی شده با اندازهجسم مطابقت داده شد. برای یک بعد جسم با اندازه &lt;span dir=&quot;LTR&quot;&gt;mm&lt;/span&gt; 5/12 میانگین اندازه تصاویر&lt;br&gt;
&lt;span dir=&quot;LTR&quot;&gt;mm&lt;/span&gt;&amp;nbsp; 629/12&amp;nbsp; به دست آمد. مقادیر به دست آمده با 05/0 = &lt;span dir=&quot;LTR&quot;&gt;p value&lt;/span&gt; اختلاف معنی داری را نشان نداد. در گام بعدی تصاویر از نظر شکل ظاهری با شکل واقعی مقایسه شد. برای اجسامی مثل: کره کائوچویی و استوانه پلاستیکی، به دلیل آرتیفکت های مربوط به بازتاب های متوالی، تصاویر بازسازی شده با جسم واقعی مطابقت نداشت. ولی برای دست انسان، کلیه گوسفند و رگ کاروتید گردن انسان سازگاری بین تصاویر بازسازی شده و جسم واقعی وجود داشت. برای کلیه انسان به دلیل حرکت کلیه در زمان اخذ ، تصاویر بازسازی شده مخدوش بود. بنابراین برای کلیه انسان باز سازی تصاویر به درستی انجام نشد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; براین اساس بازسازی تصاویر در &lt;span dir=&quot;LTR&quot;&gt;in vitro&lt;/span&gt; برای اجسامی که معادل بافت باشندمثل کلیهگوسفند و دست انسان به خوبی انجام شد. در &lt;span dir=&quot;LTR&quot;&gt;in vivo&lt;/span&gt; برای رگ کاروتید سازگازی بین رگ و تصویر آن وجود داشت.در مورد کلیه انسان به دلیل حرکت کلیه این روش جوابگو نبود.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;div&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;Ultrasound imaging is one of the common methods in medical diagnostic&lt;br&gt;
&amp;nbsp;&amp;nbsp; systems. There are many artifacts in a two dimentional image. Three dimentional&lt;br&gt;
&amp;nbsp;&amp;nbsp; imaging can be used for better interpretation and perception of an image. Since&lt;br&gt;
&amp;nbsp;&amp;nbsp; 1969 many attemps have been made in this regards, and research continues all&lt;br&gt;
&amp;nbsp;&amp;nbsp; over the world. The main goal in our research was to create three - dimentional&lt;br&gt;
&amp;nbsp;&amp;nbsp; images using conventional 2-D ultrasound systems.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; To obtain three dimentional data for construction of 3-D images, a conventional&lt;br&gt;
&amp;nbsp;&amp;nbsp; sonography with linear array transducer was used. The 2-D images of an&lt;br&gt;
&amp;nbsp;&amp;nbsp; alominume cylinder, fiber glass sphere, human hand, sheep kidney, human&lt;br&gt;
&amp;nbsp;&amp;nbsp; kidney, and carotid were taken. Using a scanner with three degree of freedom, the&lt;br&gt;
&amp;nbsp;&amp;nbsp; images locations were determined. In one of three directions, the transducer&lt;br&gt;
&amp;nbsp;&amp;nbsp; translations movement was performed. Using a stepping motor the scanner&lt;br&gt;
&amp;nbsp;&amp;nbsp; movements were achieved. High level language programming &amp;lsquo;C&amp;rsquo; were written to&lt;br&gt;
&amp;nbsp;&amp;nbsp; control the scanner. Each image slice was obtained with 1mm slice thickness step.&lt;br&gt;
&amp;nbsp;&amp;nbsp; Using appropriate image processing techniques such as filtering and interpolation,&lt;br&gt;
&amp;nbsp;&amp;nbsp; image reconstruction was performed from obtained 2-D images. These image&lt;br&gt;
&amp;nbsp;&amp;nbsp; proccesings were done using MATLAB software.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; After reconstruction images in other dimentions, the images were studied from&lt;br&gt;
&amp;nbsp;&amp;nbsp; two aspects. At the first step the size of reconstructed images compared with the&lt;br&gt;
&amp;nbsp;&amp;nbsp; main object. For one dimention of an object 12.5mm,average of images was&lt;br&gt;
&amp;nbsp;&amp;nbsp; 12.629 mm. There was not significant difference between them. In next step,&lt;br&gt;
&amp;nbsp;&amp;nbsp; images were compared with the main objects&amp;nbsp; regard their appearances. For&lt;br&gt;
&amp;nbsp;&amp;nbsp; objects such as fiber glass sphere, alominume cylinder , because of the artifacts,&lt;br&gt;
&amp;nbsp;&amp;nbsp; reconstructed images were not&amp;nbsp; exactly like main objects. But for human hand,&lt;br&gt;
&amp;nbsp;&amp;nbsp; sheep kidney, and carotid , there was proper accomodation between images&lt;br&gt;
&amp;nbsp;&amp;nbsp; and main objects. For human kidney, the obtained images were not clear.&lt;/p&gt;
&lt;/div&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; In vitro ,reconstruction of images for objects which are equal with the organs&lt;br&gt;
&amp;nbsp;&amp;nbsp; like sheep kidney and human hand was done. In vivo for carotid vessel there was&lt;br&gt;
&amp;nbsp;&amp;nbsp; accomodation between carotid&amp;nbsp; and its images. For human kidney was not done.&lt;/p&gt;
</abstract>
	<keyword_fa> تصویر سه بعدی / جایاب مکانیکی / فراصوت </keyword_fa>
	<keyword>Mecanical Locator / Three - Dimentional Images/ Ultrasound </keyword>
	<start_page>0</start_page>
	<end_page>0</end_page>
	<web_url>http://sjh.umsha.ac.ir/browse.php?a_code=A-11-185-6&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Gholamreza</first_name>
	<middle_name></middle_name>
	<last_name>Azizian</last_name>
	<suffix></suffix>
	<first_name_fa>غلامرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عزیزیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846003181</code>
	<orcid>10031947532846003181</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Saeed</first_name>
	<middle_name></middle_name>
	<last_name>Sarkar</last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سرکار</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846003182</code>
	<orcid>10031947532846003182</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Javad</first_name>
	<middle_name></middle_name>
	<last_name>Abolhasani</last_name>
	<suffix></suffix>
	<first_name_fa>محمدجواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابوالحسنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846003183</code>
	<orcid>10031947532846003183</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>