Volume 12, Issue 2 (Scientific Journal of Hamadan University of Medical Sciences-Summer 2005)                   Avicenna J Clin Med 2005, 12(2): 22-27 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Sheikh N, Goodarzi M T, Sharifi M A. Evaluation of Efficacy of Performed Dialysis According to Changes in Bone Metabolism Related Parameters in Hamadan City. Avicenna J Clin Med 2005; 12 (2) :22-27
URL: http://sjh.umsha.ac.ir/article-1-543-en.html
1- , sheikh@umsha.ac.ir
Abstract:   (3972 Views)

Introduction & Objective : Most of the CRF patients undergo dialysis to correct the CRF complications. Alterations in biochemical parameters of blood depends on the quality of dialysis. Several factors such as membrane , concentration of dialysis solutions , and dilution are involved in this process. Since the efficacy of the dialysis performed in Hamadan have not been studied previously and there was not information about the efficiency of Iranian made membrane (HD , R4 , R3 , S3) , this study was designed and performed.

Materials & Methods: In this study some biochemical parameters including Hb , Hct , alkaline phosphatase , Ca , P , total protein , urea , creatinine before and after dialysis were measured in all patients referring to dialysis center of Hamadan. After collecting the blood samples before and after the dialysis, Hb and Htc were measured using the ABX cell counter. The other parameters were measured using Technicon RA1000 autoanalyser. The mean of these parameters before and after dialysis were compared using paired t-test. The results of different membranes were compared using ANOVA.

Results: Results showed the serum level of total Ca increased 33% after dialysis (P<0.0001) while the P showed 36% decrease (P<0.0001). Alkaline phosphatase activity did not show any significant differences. Comparing the efficacy of different membrane in correction of urea and creatinine , HD membrane showed the most efficiency and R4 had the least (P<0.03). Other parameters did not show significant differences.

Conclusion: The data obtained from this study showed a significant change in Ca , P, and ALP level after dialysis . Also it was concluded that different membrane had different effect on correction of studied parameters.

Full-Text [PDF 216 kb]   (3764 Downloads)    
Type of Study: Original | Subject: Other Clinical Specialties

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Avicenna Journal of Clinical Medicine

Designed & Developed by : Yektaweb